• Standard: 802.3af PoE and 802.3at PoE+ compliant
• PoE Ports: 8 ports
• PoE Budget: 123W available for all PoE+ ports, 30W max per port
• PoE Auto Recovery*
• Up to 250m PoE transmission distance**
* This switch supports PoE Auto Recovery under Standalone Mode (managed separately without a controller) and supports manual PoE Recovery under Controller Mode (centrally managed with a controller).
** The speed of the ports that support 250m PoE transmission will be downgraded to 10 Mbps. Actual transmission distance may vary depending on the quality of the cables.
Dimensions ( W x D x H )
8.2×4.9×1.0 in (209×126×26 mm)
Surge Protection
±6kV
PERFORMANCE
Switching Capacity
20 Gbps
Packet Forwarding Rate
14.88 Mpps
MAC Address Table
8K
Packet Buffer Memory
4 Mbit
Jumbo Frame
15 KB
SOFTWARE FEATURES
Quality of Service
• Port-based/802.1p/DSCP QoS
• 8 Priority Queues
• Priority Schedule Mode
- WRR (Weighted Round Robin)
• Queue Weight Config
• Bandwidth Control
- Port-Based Rating Limit
• Storm Control
- Multiple Control Modes (kbps/pps)
- Broadcast/Multicast/Unknown-Unicast Control*
* QoS and Priority Mode are supported under Standalone Mode
L2 Features
• Static Link Aggregation
• Loop Prevention / Loopback Detection
• Flow Control
- 802.3x Flow Control
• Mirroring
- Port Mirroring
- One-to-One
- Many-to-One
- Ingress/Egress/Both
• Port Statistics
- Port Mirror Status
- Traffic Statistics
• 802.1ab LLDP
L2 Multicast
• IGMP Snooping
- IGMP v1/v2/v3 Snooping
- Fast Leave
VLAN
• MTU VLAN
• Port-Based VLAN
• 802.1Q Tag VLAN
- Max 32 VLAN Groups
- 4K VID
Transmission Method
Store-And-Forward
MANAGEMENT FEATURES
Omada App
Yes. Requires the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Centralized Management
• Omada Cloud-Based Controller
• Omada Hardware Controller
• Omada Software Controller
Cloud Access
Yes. Requires the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Zero-Touch Provisioning
Yes. Requires the use of Omada Cloud-Based Controller
Management Features
• Web-based GUI
• DHCP Client
• Cable Diagnostics
• Automatic Device Discovery*
• Batch Configuration*
• Batch Firmware Upgrading*
• Unified Configuration*
* These functions require the use of the Omada SDN Controller. Zero-Touch Provisioning requires the use of the Omada Cloud-Based Controller. Go to the Omada Cloud-Based Controller Product List to find all the models supported by the Omada Cloud-Based Controller.